EasyManua.ls Logo

Ericsson ECN320 - Page 88

Ericsson ECN320
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Line Interface
80 1553-CNH 160 0787 Uen PA2 2005-09-23
the 10 error seconds, which have defined the state of the line as
unavailable. The line becomes available again after 10 contiguous
seconds with no SES. This argument is used to set the amount of
UAS before an alarm is sent.
es-24-hours – Sets the amount of Error Seconds (ES) in an in-
terval of 24 hours that is accepted before an alarm is sent. ES is a
second with one or more errors.
ses-24-hours – Sets the amount of Severely Error Seconds
(SES) in an interval of 24 hours that is accepted before an alarm is
sent. SES is a second with 18 or more errors.
uas-24-hours - Unavailable Seconds (UAS) is a second in
which the line is defined as unavailable. The line is defined as un-
available after 10 contiguous SES. The unavailable time includes
the 10 error seconds, which have defined the state of the line as
unavailable. The line becomes available again after 10 contiguous
seconds with no SES. This argument is used to set the amount of
UAS before an alarm is sent.
<interval> - The range of interval is 0 - 900
Note: Setting the threshold value to 0 (zero) will disable the alarm. The
15 minutes always start at 0,15,30 45 minutes after the hour (start
time is line initialization). The 24 hours interval start at line initializa-
tion, and is synchronized with the 15 minutes interval.
Default Setting
0
Command Usage
This command is used to set threshold values that will determine when an
alarm is sent telling that a major or critical error affects the system.
Example
ecn330(config)# dslport 1.0.1 alarm-thresholds down-
stream es-15-minutes 1 uas-15-minutes 1 ses-15-minutes
1