Command Line Interface
146 1553-CNH 160 0787 Uen PA2 2005-09-23
show password-length
show cli-autologout
Arguments:
No arguments.
Default Setting
None.
Command Usage
This command is used to read the values of the parameters set by the sys-
tem commands.
11.6.10.16 turn
Use this command to disables the Single Board Computer (SBC) con-
nected to port 28. Only valid on the ECN330.
Command level: ecn330(config system)#.
Syntax
turn off sbc management-ip-address <ip_address>
Arguments:
<ip_address> - The external management IP address
Default Setting
None
Command Usage
The command is used to turn off the EMP functionality on the ECN330 and
run the ECN330 as a switch. Refer to ECN330 User’s Guide for information
about how to enable the SBC board with the EMP functionality.
Example
ecn330(config system)# turn off sbc management-ip-
address 172.30.3.1