SMART-2 Multi Functional Wireless Weighing Indicator User Manual
________________________________________________________________________________________________
Page 40
A sample data stream (mode1, 8 bit and point-to-point communication)
U
Display
U
‘+’
U
‘1’
U
‘2’
U
‘3’
U
‘4’
U
CR
+1234
Hex 2B
31
32
33
34
0D
+123.4
U
‘+’
U
‘1’
U
‘2’
U
‘3.’
U
‘4’
U
CR
Hex 2B
31
32
B3
34
0D
U
‘-’
U
‘1’
U
‘2.’
U
‘3’
U
‘4’
U
CR
-12.34
Hex 2D
31
B2
33
34
0D
If there is a point in the display value, hex80 is added to the ASCII value of that
digit and sent to the opposite side.
UCharacter
U
HEX
U
Character
U
HEX
0.
B0
(30+80)
5.
B5
(35+80)
1.
B1
(31+80)
6.
B6
(36+80)
2.
B2
(32+80)
7.
B7
(37+80)
3.
B3
(33+80)
8.
B8
(38+80)
4.
B4
(34+80)
9.
B9
(39+80)
An exemplary mode2 data stream (addressed communication):
If the indicator address is set to 65 (hex41), the indicator transfers the weight
information after receiving the following data from the opposite side.
(Switching on)
Addres
s
HEX
FFh
41h
If the address of the indicator is set to 0, the weight information transmission starts with
any character received from the serial communication line. It should be noted that the
indicator address can be between 0 and 255.
If more than one SMART-2 indicators are connected to the same communication line,
RS485 type communication must be set and a different address must be assigned to
each device.