EasyManua.ls Logo

ESIT Smart-2 - User Manual

ESIT Smart-2
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
A T F W Nisantepe Mh. Gelin Cicegi Sk. No:36 Cekmekoy 34794 İstanbul (216) 585 1818 (216) 585 1819 www.esit.com.tr
Smart-2 User Manual - R00
Smart-2 Multi Functional Wireless Weighing Indicator Indicator
User Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ESIT Smart-2 and is the answer not in the manual?

Summary

Legal Warning

General Details and Key Functions

Key Function

Explains the function of each button on the device for navigation and operation.

Mounting Methods

Rail Mounting Apparatus

Details the mounting process for the rail mounting apparatus.

Panel Mounting Apparatus

Details the mounting process for the panel mounting apparatus.

Indicator Information

Indicator Connections

Menu System Overview

Identity Menu

Displays serial number and version information of the indicator.

Display Settings Menu

Sets increment step (e), point location, weighing capacity, and unit of measurement.

Configuration Menu

Adjusts backlight, brightness, average filter size, eco mode, speed, and gain.

Calibration Menu

Performs zero and load calibrations for the device.

Relay 1 Menu

Configures set value, hysteresis, delay time, and contact position for relay 1.

Relay 2 Menu

Configures set value, hysteresis, delay time, and contact position for relay 2.

Analog Output (DAC) Menu

Sets lower/upper values and corresponding display values for analogue output.

Communication Settings Menu

Sets communication mode, speed, and data format.

Bluetooth and WiFi Configuration

Bluetooth Menu

Manages Bluetooth name and on/off settings for the Low Energy module.

WiFi Menu

Manages WiFi name and on/off settings for the WiFi module.

Temperature Calibration Menu

Performs temperature calibration and compensation for the device.

Reset Menu

Restores the device to its factory default settings.

Device Identity Information

Displaying the Serial Number

Procedure to display the device's serial number.

Displaying the Version Details

Procedure to display the version details of the indicator.

Display Settings

Setting the Point Location

Sets the decimal point location for screen resolution adjustment.

Increment Step Setting

Weighing Capacity Setting

Unit of Measurement Setting

Configuration Settings

Display Light Setting

Adjusts backlight brightness and enables auto light on functionality.

Average Setting

Weight Change Speed

Eco Mode Setting

Gain Setting

Display Brightness Setting

Measurement Stability

Weight Calibration

Zero Calibration

Procedure for performing zero calibration on the device.

Load Calibration

Relay Settings

Relay 1 Settings

Relay 1 Set Value Setting

Sets the value for relay 1 activation and deactivation.

Relay 1 Set Direction Setting

Relay 1 Set Hysteresis Setting

Relay 1 Delay Time Setting

Relay 2 Settings

Analog Output (DAC) Settings

Analog Output Calibration

Calibrates the analogue output for use with automation devices.

DAC Lowest Output Value (LVAL) Setting

DAC Highest Output Value (HVAL) Setting

DAC Maximum Output (DMAX) Value Setting

Communication Settings

Communication Mode Setting

Sets the communication mode (e.g., NO COMMUNICATION, ADDRESSABLE).

Indicator Address (Scale Identity No) Setting

Communication Parity Bit Setting

Communication Speed (Baud Rate) Setting

Communication Data Length Setting

Point-to-Point Communication Setting

Bluetooth Settings

Bluetooth Status Setting

Turns the device's Bluetooth feature on or off.

Bluetooth ID Setting

WiFi Settings

WiFi Status Setting

Turns the device's WiFi feature on or off.

WiFi Mode Setting

WiFi Access Point ID Setting

WiFi Station ID Setting

WiFi Name Setting

Temperature Calibration Settings

Restoring Factory Settings

Performing Taring with Tare Key

Zeroing Display Value with Zero Key

Connections and Mode Selections

Calibration Switch (P2)

Explains the function of the P2 switch for enabling calibration and settings.

Analog Output Mode Selection

0-5 V Analog Output Connection

Details the pin connections for the 0-5V analog output.

4-20 mA Analog Output Connection

Details the pin connections for the 4-20mA analog output.

Android Application Settings

Connection with WiFi Module

Guides connecting the device to a WiFi network via the Android app.

Connection with Bluetooth Module

Making Device Settings (App)

Display Settings (App)

Allows changing Decimal Point, Step, Capacity, and Unit settings via the app.

App Configuration Settings

Configuration Settings (App)

Allows setting Backlight Mode, Average Count, Speed, Eco Mode, Gain, and Brightness via the app.

Relay Settings (App)

Allows configuring Relay 1 and Relay 2 settings via the app.

Analog Output (DAC) Settings (App)

Allows configuring LVAL, HVAL, and DMAX settings via the app.

App Communication Settings

Communication Settings (App)

Allows configuring communication mode, identity, parity, baud rate, and bit length via the app.

WiFi Connection Setting (App)

Guides connecting to a local network using WiFi via the Android app.

App Calibration Setting

App Temp Calibration Setting

Error Codes

ESIT Smart-2 Specifications

General IconGeneral
CategoryMeasuring Instruments
Resolution0.01Ω
Test Current200 mA
DisplayLCD
Operating Temperature0°C to 40°C
Storage Temperature-10°C to 50°C
Weight0.5 kg
Power Supply4 x AA batteries