746 C - 844 C 9 532150 - Rev.A
Translation of the original instructions
ENGLISH
■ Safety functions of E781
Inputs Programming Functions
Protection
type according
to EN 12453
Device perfor-
mance level
E781 perfor-
mance level
OP_H
CL_H
So , Sc
Dead-man command without
latching
A or B –
Pl c Category
2
FSW OP
FSW CL
Failsafe enabled on OUT1/OUT2
1F = 1/ 2/ 3
o1 / o2 = 01
Contact prevention using presence
detection devices (ESPE)
E
Pl c Category
2
Pl c Category
2
Failsafe enabled on OUT1/OUT2
1F = 1/ 2/ 3
o1 / o2 = 01
Ph
= no, Op = Y
Force limitation by means of sensitive
edges with NC contact (PSPE)
C
EDOP+
EDOP -
EDCL+
EDCL -
OE, CE = 1r/ 2r/ 3r/ 4r
Force limitation by means of resistive
sensitive edges 8.2 k (PSPE)
C
Pl c Category
2
Pl c Category
2
OE, CE = nc
Failsafe enabled on OUT1/OUT2
3F = 1/2/3
o1
/ o2 = 01
Force limitation by means of sensitive
edges with NC contact and TEST input
(PSPE)
STOP
Failsafe=enabled on OUT1/OUT2
2F = 1
o1
/ o2 = 01
Safety STOP for pedestrian door
integrated in the sliding leaf
or
Contact prevention using presence
detection devices (ESPE)
E –
Pl c Category
2
Encoder
EC = 01/02/03
FO
, So, Sc, ro, rc, dS
Intrinsic force limitation C –
Pl c Category
2
BUS 2easy BUS 2easy sensitive edges
Force limitation by means of sensitive
edges BUS 2easy
(PSPE)
C
Pl c Category
2
Pl c Category
2
■ Additional protection functions
Inputs Programming Functions
Protection
type according
to EN 12453
Device perfor-
mance level
E781 perfor-
mance level
FSW OP
FSW CL
Failsafe enabled on OUT1/OUT2
1F = 1/ 2/ 3
o1 / o2 = 01
or
Periodic inspection at a mini-
mum interval of 6 months
Additional devices to reduce the
likelihood of contact
D – –
Bus 2EASY BUS 2easy photocells
Additional devices to reduce the
likelihood of contact
D – –