User Manual HOW TO … February 16, 2010
Xynergi Media Production Centre Page 91
Get Ready
Press the green Mixer button.
Press the
mix ON button so that it is illuminated.
Operation
Pressing auto safe brings the SEL display to the screen.
Any path you select will be safe from changes to Automation data.
You may need to select
Tracks, Lives or Buses first, then press the path buttons that you want
to isolate.
Press
exit to return to the Mix menu.
Files
Overview
Automation data is treated separately from other Project files.
This guide shows you how.
Get Ready
Press the green Mixer button.
Press the
mix ON button so that it is illuminated.
Press the
file button.
Operation
The file menu uses a list of files shown in the Pad. Use the file menu soft keys as follows:
System Mix if YES, saves the current mix with the Project. This includes a statix mix, plus the
most recent version of the automation i.e. the one currently in memory (if any).
Sort determines the display order of mix files
Save Press this soft key, then type a name and press ENTER.
Load Loads the mix currently showing in the Pad list.
New Mix Zeroes all automation data
Delete Removes the mix file currently showing in the Pad.
Carry Over lets you load a new Project with the current mix
Automation Curves
Automation data for tracks can be shown on the Edit Screen using the following command
sequence:
ViewSmart PaneAutomation, or by pressing the
Curves soft key in the Mix Menu.