P. Description
8 Terminals (2) for the earth connection wires
9 Hooks (2) to secure Main module on the
backplate
10 Main Module (see figure 3)
11 Cable entry for channeled undertrack cables:
power cable
12 Anchors (2) for power cable
13 Switching power supply (see figure 4)
14 Backplate anchor screw locations
15 Main module supports (2)
16 Power cable for Main module
17 Opening (2) to secure batteries
18 Location for 2 batteries 12V, 7Ah or 12Ah
19 Backplate auxiliary anchor screw locations (2)
20 Cable entry (3) for channeled undertrack cables
21 Cables anchor (3)
22 Screw to secure main module
23 Tubular spirit level
24 Connector for FC500IP Module
25 Opening to insert the zone location text strip
26 USB port
P. Description
27 Power supply main module connector
28 RS485 Serial port & battery connection termi
-
nals
29 Programmable outputs and auxiliary power
supply terminals
30 Buzzer (not visible)
31 Terminals for future use
32 Jumper J5 to reset the installer PIN n. 1 to the
factory default (0000)
33 SC outputs
34 Jumper for the exclusion of the Earth Fault:
// = Earth Fault detected (Default);
oo = Earth Fault ignored
35 FIRE and FAULT relay outputs
36 Terminals for phone line connection
37 Loop1
38 Loop2
39 Loop3
40 RS232 Serial (PC link)
41 Hole for Main module fixing
INSTALLATION 15
FIRE
FAULT
-
LE LI
NC NO
C
NC NO
C
J1
+SC1
+SC2
MIC SPKBLK RED OC1 Oc2
24R 24A
RS485
+
-
24V
BAT
-
+
PSU
PC LINK
ADD ON
SH
+ LEFT - +RIGHT-
LOOP1
SH
+ LEFT - +RIGHT-
LOOP2
SH
+ LEFT - +RIGHT-
LOOP3
B078-P0
LCD
J5
ABC
JKL
STU
ESC
DEF
MNO
VWX
GHI
PQR
YZ
1
4
7
2
5
8
0
3
6
9
?
A
D
BC
EF
]
SILENCE BUZZER
SILENCE/RESOUND
SOUNDERS
RESET
INVESTIGATION
DELAY
LAMP TESTEVAC
ABC
JKL
STU
ESC
DEF
MNO
VWX
GHI
PQR
YZ
1
4
7
2
5
8
0
3
6
9
?
A
D
BC
EF
]
FIRECLASS FC501
1
2
3
4
GENERAL FAULT MORE INFO
SYSTEM FAULT
SOUNDERS
SILENCED
FIRE SIGNAL
FAULT
FIRE SIGNAL
ON
POWER SUPPLY
FAULT
SOUNDERS
FAULTS/DIS
EARTH FAULT
DISABLED
BATTERY
TROUBLE
TEST
POWER ON DAY MODE ON
CONTROLS
ON
SILENCE BUZZER
SILENCE/RESOUND
SOUNDERS
RESET
INVESTIGATION
DELAY
LAMP TESTEVAC
FIRE
MSACMNEEFC501D 0.0
36 35 34 33 32 31 30 2
9
2
8
27
26
25
41
40
39
38
37
24
1
2
3
4
GENERAL FAULT MORE INFO
SYSTEM FAULT
SOUNDERS
SILENCED
FIRE SIGNAL
FAULT
FIRE SIGNAL
ON
POWER SUPPLY
FAULT
SOUNDERS
FAULTS/DIS
EARTH FAULT
DISABLED
BATTERY
TROUBLE
TEST
POWER ON DAY MODE ON
CONTROLS
ON
SILENCE BUZZER
SILENCE/RESOUND
SOUNDERS
RESET
INVESTIGATION
DELAY
LAMP TESTEVAC
FIRE
MSACMNEEFC501D 0.0
Figure 3 Main module Parts