EasyManua.ls Logo

FireClass FC501 - Panel Details Menu; Communication Menu; Language Menu; Firmware Update Menu

FireClass FC501
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- Panel
- Communication
- Panel Language
- Firmware Update
- Screen Saver
- Account.
n
Panel Details Menu
In this window, it is possible to enter the name of the Pa
-
nel/Customer. By clicking on the icon it is possible
to check the firmware version of MainBoard, Loop con
-
troller, User Interface, Repeater and FC500FMI modu
-
le. Click on the icon to restore the Control Panel to
the factory default.
Click on the icon to open the Installation Manual.
n Communication Menu
In the Communication menu you can choose the con-
nection mode between the Panel and the PC: TCP/IP,
RS232 or USB. Click on the icon , to update the type
of connection, and click on the TEST button to verify the
functionality of the connection status. In the TCP/IP
mode, it is necessary to enter the FC500IP parameters
and the Installer password already in the system.
The IP Module screen is used to program the parameters
corresponding to the IP Module as described below.
Ø
IP address Enter the IP address assigned to the IP
Module you wish to program or, if DHCP (dynamic IP
address) mode has been selected, contact the net
-
work administrator to request details of the IP ad
-
dress assigned to the IP Module. Alternatively,
follow the procedure outlined in the “View IP ad
-
dress” paragraph to view the IP address on the con
-
trol unit display.
The default setting is 192.168.0.101.
Ø
IP Module port Enter the details of the port as
-
signed to the IP Module you wish to program
(contact the network administrator).
The default setting is 3064.
Ø
IP Module code Enter the access code assi
-
gned to the IP Module you wish to program. The
default setting is 5555.
Encryption key Enter the encryption key assi
-
gned to the IP Module you wish to program. The de
-
fault setting is 32 zeros.
n
Language Menu
The Language menu allows you to change the system
language (User Interface or Repeater) to any of the lan
-
guages currently loaded. In the Loaded Language sec
-
tion, click on Change System Language , then select
the language and the device (User Interface or Repeater)
click-on to override the language in the Control panel
memory. As soon as the download of the new language is
completed, the panel will start to use it, and update any pe
-
ripherals, if necessary.
n Firmware Update menu
Click on “Firmware Update”: the window (see figure 19)
will be shown. From a source file, this option allows the
Firmware Update of all system interface: Mainboard,
User interface, Loop controller, Repeater.
+
If the FC500REP repeater has a Firmware V3 or
less, and the language is Italian while on the Pa-
nel there is English, the installer after the firmwa-
re update, have to realign the strings of
languages, performing the process of language
change (see Program 8 Key-System)
n
ScreenSaver menu
In the ScreenSaver menu it is possible to insert 4 lines
of text (such as Installer address/telephone) that will be
loaded on the display of the User Interface when the pa
-
nel is in the stand-by status. The four row could be: Ste
-
ady or Scroll or Blink.
PC PROGRAMMING 31
Figure 20 Communication window. Figure 21 Account window.
Figure 22 Devices programming window

Table of Contents

Related product manuals