DAD 143.x User Manual Profinet Rev.1.0.0 October 2022 Page 83 of 95
0x2007
0x00
0x01
0x02
0x03
0x04
0x00C0
0x00C1
0x00C2
0x00C3
0x00C4
Number of entries.
Not used.
Not used.
Not used.
Software reset.
UI8
UI8
UI8
UI8
UI8
ro
rw
rw
rw
wo
0x04
0
0
0
-
Number of entries.
Not used.
Not used.
Not used.
Software reset SR command.
Index
Sub-
Index
Acyclic
Index
Name
Type
Attri-
but
Default
Value
Meaning
0x2100
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
0x15
0x16
0x17
0x18
0x19
0x00E0
0x00E1
0x00E2
0x00E3
0x00E4
0x00E5
0x00E6
0x00E7
0c00E8
0x00E9
0x00EA
0x00EB
0x00EC
0x00ED
0x00EE
0x00EF
0x00F0
0x00F1
0x00F2
0x00F3
0x00F4
0x00F5
0x00F6
0x00F7
0x00F8
0x00F9
Number of entries.
Analog action.
Analog high.
Analog low.
Filter setting.
Not used.
Logic outputs.
Logic inputs.
Measure Time.
Filter Mode.
No motion Range.
No motion Time.
Output Mask.
Not used.
Start Delay.
Not used.
Not used.
Update Rate.
Zero Tracking.
Not used.
Not used.
Analog mode.
Pre-filter.
Preset Tare.
Not used.
Analog Reference.
UI8
UI32
UI32
UI32
UI8
UI32
UI8
UI8
UI16
UI8
UI16
UI16
UI8
U32
UI16
UI32
UI32
UI8
UI8
UI32
UI32
UI32
UI8
I32
I32
I32
ro
rw
rw
rw
rw
rw
rw
ro
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
0x19
0
0
0
3
0
-
-
0
0
1
1000
0
0
0
0
0
0
0
0
0
0
1
0
0
0
Number of parameters.
Analog action AA command.
Analog high value AH command.
Analog low value AL command.
Filter setting FL command.
Not used.
Digital Outputs IO command.
Digital Inputs IN command
Measuring Time MT command.
Filter mode FM command.
No-motion range NR command.
No-motion time NT command.
Digital outputs mask OM command.
Not used.
Start Delay SD command.
Not used.
Not used.
Update rate UR command.
Zero track (TAC protected) ZT command.
Not used.
Not used.
Analog mode AM command.
Pre-filter PF command.
Preset Tare SP command.
Not used.
Analog Reference AR command

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flintec DAD143 Series and is the answer not in the manual?

Flintec DAD143 Series Specifications

General IconGeneral
BrandFlintec
ModelDAD143 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals