© Flytec USA, 2007 – 2014 Printed on 100% post-consumer recycled paper
Setting Description Reference Factory Default
Vario responsiveness - range 0 (slow) to 4 (fast)
Averager (INT) or netto vario; averager period (1–30
sec)
Minimum strength of thermal to be tracked by last
thermal feature (100–600 ft/min)
Time interval over which climb rate is averaged in the
previous thermal (0.5–10 min)
Frequency of ascent tone, modulation, frequency of
sink tone, acoustic integrator, pitch
1200 Hz; Mod = 5; 700
Hz Damp = 8;Pitch = 3:
Threshold for ascent tone (0–80 ft/min/ 0–0.4 m/sec)
4 = 0.04 m/sec (8
ft/min)
Set lower threshold for nascent thermal tone;
enable/disable tone; set beep/pause ratio for tone
Descent rate required to sound sink alarm (10–2000
ft/min)
True or Indicated air speed;
Speed range upper 19–54 mph; lower 12–37 mph
True air speed;
upper speed range
Sensor on/off; Pitot sensor 90 to 150 %
True air speed;
upper speed range
True air speed;
upper speed range
Speed threshold and altitude limit
Total energy compensation range 0–99%
Always, full auto, semi-auto start/end of flight recording
Ground speed & altitude change for Flight Acceptance
Time interval per track log point (1–60 sec)
Delay for McCready audio after leaving lift, acoustic
dead band in ft/min (m/sec)
Acoustic alarm when within warning distance to loaded
airspace
Use polar set 1 or 2, sink rate/air speed pair, altitude of
data
25 mph @ 197 ft/min;
47 mph @ 630 ft/min;
@ 1000’
Set proximity to cylinder and mode for auto zoom
Glider class for OLC (HG Rigid Wing or HG Flexible
Wing or Paraglider)
Your ham radio call sign for OLC
It is always possible to reset all of the user settings back to the factory settings using Menu>Clear/Initialize
memory>Initialize EEPROM. Important! All flight records, waypoints and routes will be deleted if you reset the