EasyManua.ls Logo

Fronius TPS 320i - Page 104

Fronius TPS 320i
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
104
I ... Welding current v
D
... Wire feed speed
Penetration stabiliser = n m/min (activated)
Specifying a value for the penetration stabiliser ensures a constant arc length without
large current variations if the stick out is changed (s
1
==> s
2
).
The penetration (x
1
, x
2
) remains virtually unchanged and stable.
Penetration stabiliser = 0.5 m/min (activated)
To minimise the change in welding current if the stick out is changed (s
1
==> s
3
), the wire
feed speed is increased or reduced by 0.5 m/min.
In the example shown, the stabilising effect is obtained without a change in current up to
the set value of 0.5 m/min (Position 2).
I [A]
v
D
[m/min]
1
2
1
2
h
s
1
s
2
x
1
x
2
t [s]
s
1
< s
2
x
1
= x
2
I [A]
v
D
[m/min]
1
3
1 2
3
h
s
1
s
3
x
1
x
3
t [s]
s
1
< s
3
x
1
> x
3
2
0,5 m/min

Table of Contents