155
EN
Specify the functions that a user can carry out in this role
- Select functions by turning the adjusting dial
- Press the adjusting dial
- Select settings from the list
- Press the adjusting dial
Select "OK"
Executable functions within a role
Function Setting range
Role name Editing role name using the keyboard
Time before automatic log off off / 30s / 60s / 5min / 10min / 30min / 1h
Enable Welding disabled / enabled
Save job
Jobs
Optimise job
Correction limits
Save pre-setting for job
Welding Process
Process
Mode
Filler metal
Change the consumables settings
Process parameters
General
Start/end of welding
Gas-Setup
R/L-check / alignment
Process control
TIG/electrode setup
SynchroPulse
Process mix
Components
Components
System calibration
Arc break monitoring
Wire stick setting
Wire end setting