37
EN
Installation
StandUp termi-
nal: Installation
and fixing
WARNING!
A device that topples over can easily kill someone.
Set up the device in a dry and enclosed environment on a firm, supportive, horizontal sur-
face, making sure it is stable. Trained personnel must fasten the StandUp terminal to the
wall or anchor it firmly to the floor using the holders provided.
To allow the device to acclimatise, do not plug in the mains cable until the device has been
assembled and do not switch on the device for 4 hours after setting up.
The StandUp terminal is supplied in 2 parts. The StandUp terminal comes with two keys.
One key locks the upper part containing the technology. The second key is for the lower
part.
From the plastic film supplied, remove the 4 Allen screws and washers for fastening
the lower part to the upper part
Place the upper part on the lower part
Secure the upper part to the lower part
using the 4 Allen screws (1) M8 x 80
mm and washers supplied
Mounting on the wall:
Fasten the supplied mounting brackets
(2) to the top of the StandUp terminal
as shown in the illustration
Fasten the StandUp terminal with the
mounting brackets (2) and the supplied
screws
Mounting on the floor:
Fasten the StandUp terminal to the
floor via the holes in the floor plate
using the supplied screws (3) and sui-
table dowels
1
2
(2)
(1)
(3)
(2)
(3)
3
4
5
4