63
to3 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the wirefeeder motor
Remedy: Allow wirefeeder to cool down
to4 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in welding torch
Remedy: Allow welding torch to cool down
to5 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in cooling unit
Remedy: Allow cooling unit to cool down.
to6 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the power source transformer
Remedy: Allow power source to cool down
tu0 | xxx
Note: xxx stands for a temperature value
Cause: Undertemperature in the power source primary circuit
Remedy: Place power source in a heated room and allow to warm up
tu1 | xxx
Note: xxx stands for a temperature value
Cause: Undertemperature in the power source control gear
Remedy: Place power source in a heated room and allow to warm up
tu2 | xxx
Note: xxx stands for a temperature value
Cause: Undertemperature in the power source secondary circuit
Remedy: Place power source in a heated room and allow to warm up
tu3 | xxx
Note: xxx stands for a temperature value
Cause: Undertemperature in the wirefeeder motor
Remedy: Place wirefeeder in a heated room and allow to warm up
tu4 | xxx
Note: xxx stands for a temperature value
Cause: Undertemperature in the welding torch
Remedy: Place welding torch in a heated room and allow to warm up
tu5 | xxx
Note: xxx stands for a temperature value
Cause: Undertemperature in the cooling unit
Remedy: Place cooling unit in a heated room and allow to warm up
tu6 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the power source transformer
Remedy: Place power source in a heated room and allow to warm up
Displayed service
codes
(continued)