64
Displayed service
codes
(continued)
Err | tf0
Cause: Faulty temperature sensor in the power source primary circuit
Remedy: Contact After-Sales Service
Err | tf1
Cause: Faulty temperature sensor in the power source control gear
Remedy: Contact After-Sales Service
Err | tf2
Cause: Faulty temperature sensor in the power source secondary circuit
Remedy: Contact After-Sales Service
Err | tf3
Cause: Faulty temperature sensor in wirefeeder motor
Remedy: Contact After-Sales Service
Err | tf4
Cause: Faulty temperature sensor in welding torch
Remedy: Contact After-Sales Service
Err | tf5
Cause: Faulty temperature sensor in cooling unit
Remedy: Contact After-Sales Service
Err | tf6
Cause: Faulty temperature sensor in power source transformer
Remedy: Contact After-Sales Service
no | Prg
Cause: No preconfigured program has been selected
Remedy: select a configured program
EPG | 1 to EPG | 6
Cause: Welding database power source defective
Remedy: Contact After-Sales Service
EPG | 17 to EPG | 21
Cause: Power source software error
Remedy: Switch off the power source, wait for 10 seconds and then switch it
on again. If you have tried this several times and the error keeps
recurring, contact After-Sales Service.
Ebo | 2 and Ebo | 3
Cause: Fault in the power source control gear
Remedy: Switch off the power source, wait for 10 seconds and then switch it
on again. If you have tried this several times and the error keeps
recurring, contact After-Sales Service.