Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
762
Detailed Configuration Information
Data Transmission Method
Specify Storage System Name for HELO/EHLO Announcement when Sending E-Mail
Use S/MIME
Description Select whether to "Split" or "Do not Split" into the specified size.
Select "Split large E-Mail into multiple E-Mails" or "Split large data into multiple E-Mails",
and specify the segment size, when segmenting outgoing mail.
If the mail server does not allow the sending of segmented mail using "Split large E-Mail
into multiple E-Mails", select "Split large data into multiple E-Mails" or "Do not Split".
Input condition/
Display contents
Split
Outgoing mail is segmented.
- Split large E-Mail into multiple E-Mails
Outgoing mail is segmented into the specified size (64 - 6400KB).
- Split large data into multiple E-Mails
The file attached to the E-mail is segmented into several pieces, turned into one
E-mail in the specified size (64 - 512KB), and sent in several transmissions.
Do not Split
The message is sent as one E-mail without being segmented.
Description Select "Specify" or "Do not specify" for the ETERNUS DX name for HELO/EHLO
announcement when sending mail.
When "Specify" is selected, input the domain.
The domain of the HELO/EHLO Announcement must be specified in the mail protocol.
If "Do not specify" has been selected, E-mails are sent using the strings after the "@" of
the sender mail addresses as domains.
If the mail server does not allow using the section after the "@" of the sender mail
address as the domain, select "Specify" and input the appropriate domain.
Input condition/
Display contents
Specify
Up to 63 alphanumeric characters and symbols (except space)
Do not specify
Description Select whether or not to use S/MIME.
S/MIME is a standard relating to encryption of E-mails and electronic signatures. Using S/
MIME prevents E-mails from being sniffed, spoofed, and falsified. This item is available
when one of the following conditions applies:
"Do not Split" is selected for the data transmission method
"Split" is selected for the data transmission method and "Split large data into
multiple E-Mails" is specified
Input condition/
Display contents
Use
Not use