Appendix A Parameter List
A.4 Connectivity Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
879
A.4.6.2 Set FC/FCoE Host QoS
For details about this function, refer to "4.7.7 Set FC/FCoE Host QoS" (page 489).
For the factory default settings for this function, refer to "Appendix B Set FC/FCoE Host QoS" (page 1000)
.
FC/FCoE Host QoS Setting
Bandwidth Limit
A.4.6.3 Set iSCSI Host QoS
For details about this function, refer to "4.7.8 Set iSCSI Host QoS" (page 490).
For the factory default settings for this function, refer to "Appendix B Set iSCSI Host QoS" (page 1000)
.
iSCSI Host QoS Setting
Bandwidth Limit
Description Select the maximum performance in IOPS (throughput value).
If the bandwidth limit is not to be configured (the bandwidth is not to be limited), select
"Unlimited".
Input condition/
Display contents
Unlimited
15000 IOPS (800 MB/s)
12600 IOPS (700 MB/s)
10020 IOPS (600 MB/s)
7500 IOPS (500 MB/s)
5040 IOPS (400 MB/s)
3000 IOPS (300 MB/s)
1020 IOPS (200 MB/s)
780 IOPS (100 MB/s)
600 IOPS (70 MB/s)
420 IOPS (40 MB/s)
300 IOPS (25 MB/s)
240 IOPS (20 MB/s)
180 IOPS (15 MB/s)
120 IOPS (10 MB/s)
60 IOPS (5 MB/s)
Refer to "FC/FCoE Host QoS Setting" (page 879) in "A.4.6.2 Set FC/FCoE Host QoS" (page 879) for details.