BX900 S2 Upgrade and Maintenance Manual 113
Connection blades
8.2.1.3 Removing connection blade dummy module
Figure 21: Removing a dummy connection blade module
Ê Press the handles of the dummy module inward and pull it out of the slot.
V CAUTION!
Keep the dummy modules for future use.
Always replace connection blade dummy modules into unused
connection blade slots to comply with applicable EMC regulations and
satisfy cooling requirements.
8.2.1.4 Installing a single-width connection blade
Ê Unpack the connection blade.