BX900 S2 Upgrade and Maintenance Manual 47
Basic hardware procedures
4.1.3.1 Global Error indicator
Ê Check the Global Error indicator on the front panel or management blade of
the system unit (see section "Connectors and indicators" on page 179).
Ê For further diagnostics, proceed as follows:
Check the status frame of the management blade web interface, see the
"PRIMERGY BX900 Blade Server Systems ServerView Management
Blade S1 User Interface Description".
Check the System Event Log (SEL) as described in section "Viewing the
SEL" on page 71.
4.1.3.2 Customer Self Service (CSS) indicator
Ê Check the CSS indicator on the front panel or management blade of the
system unit (see section "Connectors and indicators" on page 179).
Indicator Status Description
Global error
indicator
off no critical event (non CSS component)
orange on
prefailure detected (non CSS component),
requires (precautionary) service
intervention
orange
flashing
non CSS component failure or software /
agent related error, requires service
intervention
Indicator Status Description
CSS indicator
off no critical event (CSS component)
yellow on prefailure detected (CSS component)
yellow
flashing
CSS component failure