76 Upgrade and Maintenance Manual BX900 S2
Basic software procedures
© cognitas. Gesellschft für Technik-Dokumentation mbH 2011 Pfad: C:\Programme\FCT\tim_app\tim_local\work\WALTER\OBJ_DOKU-13655-001.fm
5.2.7 Saving connection blade settings
After replacing and configuring a connection blade you must create a backup
copy of the connection blade settings.
Saving out-of-band connection blade settings
Perform the following steps to create a backup copy of the out-of-band
configuration data of a connection blade.
Ê If not done yet, login to the management blade web interface, see section
"Accessing the management blade web interface" on page 44.
Ê Open the System – Connection Blades – Connection Blade-x menu for the
desired connection blade.
Ê Open the Backup/Restoration tab.
Ê In the Backup Configuration box of the Connection Blade Out-Of-Band
Configuration frame select the backup medium.
– Select Memory to store the backup file in the management blade memory.
– Select USB to store the backup file in a USB memory stick.
I This option is only displayed if a USB memory stick is connected
to the management blade.
– Select Local File to store the backup file in the file system of the field
service terminal.
I The filename of the backup copy will be automatically generated
consisting of an identification tag and the current date and time.
Ê Click the Backup button.
Saving enhanced connection blade settings
Perform the following steps to create a backup copy of the enhanced
configuration data of a connection blade.
Ê If not done yet, login to the management blade web interface, see section
"Accessing the management blade web interface" on page 44.
Ê Open the System – Connection Blades – Connection Blade-x menu for the
desired connection blade.
Ê Open the Backup/Restoration tab.