BX900 S2 Upgrade and Maintenance Manual 69
Basic software procedures
Ê Enter 4 to set the gateway address of subnet mask.
Ê Enter 5 to set the TFTP file name.
Ê Enter 0 to leave the Network Paramenters menu.
Ê Connect the FST to the service LAN connector of the management blade,
see pos. #4 or 5 in "Connectors on the management blade" on page 183.
I The FST must be on the same LAN with the same subnet as the
service LAN port.
Ê Enter 1 to open the Upgrade Firmware from Network menu.
Ê Open the Management Blade Update Enable menu.
Ê Select Single MMB firmware update enable to start the firmware update
process.
Wait until the firmware update is completed.
Ê Remove the management blade from the system unit. This is done in the
same way as described in section "Removing a single-width connection
blade" on page 116.
Ê Open the management blade, as described in section "Opening the
management blade" on page 149 and set the Recovery Mode DIP switch
OFF, see "Management Blade Settings" on page 204.
Ê Close the management blade in the opposite order to that described in
section "Opening the management blade" on page 149.
Ê Reinstall the management blade into the system unit, "Installing the
management blade" on page 145.