During the test run
Visually check that the fraction collector wash is performed.
Evaluate the test
To evaluate the result, do the following:
Check that the fractionation marks in the chromatogram correspond to the filled
wells and tubes and that there is minimal spillage. For further information on delay
volumes and fractionation marks, see Delay volume, on page 220.
ÄKTA avant 25
Check that correct volumes, 2 ml per well, are collected in wells 1A1 to 1A4 and 6A1
to 6A4.
ÄKTA avant 150
Check that correct volumes, 20 ml per tube, are collected in tubes 1A1 to 1A4 and
6A1 to 6A4.
248 ÄKTA avant User Manual 29035184 AE
6 Performance tests
6.3 Built-in Fraction collector test