EasyManua.ls Logo

GE Hydran M2-X - Page 147

GE Hydran M2-X
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 147
Hydran* M2-X Instruction Manual
MA-029 Rev. 1.0, 30-Jul-18
Inductive load: 1.5 A (ac/dc)
Communications
Ports
One RS-232 port for local laptop computer connection
One RS-485 port for connection to local Hydran network or
remote communication
Optional
Communications
Port
1 of the following to be specified when ordering:
Integrated serial to Ethernet 10/100BaseT; Part Number
17046
Integrated Fiber Optic Ethernet 100BaseFX, ST Multimode;
Part Number 18321
Integrated dial-up Modem V.92/56k; Part Number 16868
Optional I/O
Up to 4 of the following to be specified when ordering:
General-purpose 420 mA analog input; 2,000 V RMS
isolation; Part Number 16528
Analog 420 mA output; 500- maximum loading; 2,000 V
RMS isolation; Part Number 16529
Dual digital inputs for dry contacts; internal wetting 24 VDC;
2,000 V RMS isolation; Part Number 17464
MISCELLANEOUS
Enclosure
Type NEMA 4X (IP56)
Cast aluminum, powder pint, white
External dimensions: 315 mm long x 219 mm wide x 196 mm
high (12.4 x 8.63 x 7.72 in)
For details, see Section A.2.1.
Electronic
Modules
Totally encased CPU and I/O electronics
Sensor Heating
Heater plate to maintain sensor between 15 and 65 °C (59 and
149 °F) in normal transformer operating conditions to force oil
convection
Oil Temperature
Oil at the valve: -40 to +90 °C (-40 to +194 °F)
Oil at the valve up to 105 °C (221 °F), with optional finned,
high-temperature adaptor, Part Number 18065
Possible short-duration exposure: Oil up to 120 °C (248 °F)
Oil Pressure
Vacuum-resistant sensor; 0700 kPa (0100 psia)
Power Supply
90-132 Vac, 180-264 Vac, 47-63 Hz, 650 VA maximum
EMC
Compatibility
Meets standards ENV 50204, EN 55022, IEC 60255-22-1, EN
61000-3-2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN
61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11

Table of Contents