EasyManua.ls Logo

gefran SIEIDrive ADL300

gefran SIEIDrive ADL300
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADL300 • Functions description and parameters list 89
To select set 1 manually, set this parameter to “One”.
Otherwise select the desired source.
4 Modify the parameters in set 1 as necessary.
5 Save the parameters.
You can change the set being used by changing the source selected in parameter 3302 Par set select src. This can only
be changed with the drive disabled.
When the double parameter set is active, the number of the set being used is shown next to the number of each parameter
on the keypad.
Modifying and saving parameters:
When the double parameter set is active, any parameters that need to be the same in the two sets must be modied in
each set separately.
Parameters are only saved in the set that is active at the time. To save both sets, you must rst save one and then select
and save the other.
Note! Any changes to the parameters regarding the “parameter sets”, performed when enabled, will be lost at the next switching unless a Par set 0
to 1 copy command is sent.
To save data permanently (even when the drive is switched off), send the Save parameters command (DRIVE CONFIG menu).
20.6 - FUNCTIONS/SPEED CAPTURE
Note! This menu is not displayed if the lift application is enabled
20.7 - FUNCTIONS/COMPARE
This function allows the comparison among two signals or values.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.7.1 3650 Dig compare input 1 perc FLOAT 32BIT 0.0 -200.0 200.0 ERW FVS
Setting of the digital value of the rst element of comparison.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.7.2 3652 Dig compare input 2 perc FLOAT 32BIT 0.0 -200.0 200.0 ERW FVS
Setting of the digital value of the second element of comparison.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.7.3 3660 Compare input 1 src LINK 32BIT 3650 0 16384 ERW FVS
Selection of the origin (source) of the signal to be used as the rst term of comparison. The values that can be selected in
the compare function are listed in the “L_CMP” selection list.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.7.4 3662 Compare input 2 src LINK 32BIT 3652 0 16384 ERW FVS
Selection of the origin (source) of the signal to be used as the second term of comparison. The values that can be selected
in the compare function are listed in the “L_CMP” selection list.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
20.7.5 3670 Compare function ENUM Nessuna 0 8 ERW FVS
Setting of the compare function between Compare input 2 and Compare input 1 to enable Cmp output.
0 None
1 Inp1=Inp2
2 Inp1!=Inp2
3 Inp1<Inp2