Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.1 250 Output current A FLOAT 16/32BIT 0.0 0.0 0.0 R FVS
The drive output current is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.2 252 Output voltage V FLOAT 16/32BIT 0.0 0.0 0.0 R FVS
The drive line voltage output is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.3 254 Output frequency Hz FLOAT 16/32BIT 0.0 0.0 0.0 R FVS
The drive output frequency is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.4 628 Ramp setpoint rpm INT16 16/32BIT 0 0 0 R FVS
The ramp reference is displayed. This is the speed value the drive must reach at the end of the ramp.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.5 664 Speed setpoint rpm INT16 16/32BIT 0 0 0 R FVS
The speed reference is displayed. This is the value measured at the output of the speed reference circuit.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.6 260 Motor speed rpm INT16 16/32BIT 0 0 0 R FVS
The actual output speed of the motor is displayed (in FOC = speed measured by the encoder, in SLS/VF = speed esti-
mated by the drive).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.7 270 DC link voltage V FLOAT 16/32BIT 0.0 0.0 0.0 ER FVS
The direct voltage of the intermediate circuit capacitors is displayed (DC-Bus).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.8 272 Heatsink temperature °C INT16 16BIT 0 0 0 ER F_S
The temperature measured by the linear sensor integrated in the IGBT modules is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.9 280 Torque current ref A FLOAT 16/32BIT 0.0 0.0 0.0 ER F_S
The current reference used for torque control is displayed (in the sensorless vector and eld-oriented vector modes).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.10 282 Magnet current ref A FLOAT 16/32BIT 0.0 0.0 0.0 ER FVS
The magnetizing current reference is displayed (in the sensorless vector and eld-oriented vector modes).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.11 284 Torque current A FLOAT 16/32BIT 0.0 0.0 0.0 ER FVS
The actual torque current value is displayed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
1.12 286 Magnet current A FLOAT 16/32BIT 0.0 0.0 0.0 ER FVS
The actual magnetizing current value is displayed.

Table of Contents

Other manuals for gefran SIEIDrive ADL300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran SIEIDrive ADL300 and is the answer not in the manual?

gefran SIEIDrive ADL300 Specifications

General IconGeneral
Brandgefran
ModelSIEIDrive ADL300
CategoryInverter
LanguageEnglish

Related product manuals