112 ADL300 • Functions description and parameters list
PARAMETERS ON SELECTION LISTS, BUT NOT DISPLAYED ON KEYPAD
This list reports the parameters that are not displayed in the keyboard while they are part of the selection lists. These parameters
can be used as SOURCE of the input signals for the function block. (Refer to section A – Programming).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 262 Motor speed nofilter rpm INT16 16BIT 0 0 0 ER FVS
This parameter indicates the unltered motor speed.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 362 Drive overload trip BIT 16BIT 0 0 1 ER FVS
This signal indicates that the drive is in the overload alarm condition.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 366 Drive overload 80% BIT 16BIT 0 0 1 ER FVS
This signal indicates that the drive has reached 80% of the thermal image accumulator (drive overload).
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 626 Ramp ref out mon rpm INT16 16BIT 0 0 0 ER FVS
This parameter displays the reference value output of the ramp remference function block.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 760 Ramp out mon rpm INT16 16BIT 0 0 0 ER FVS
This parameter displays the reference value output of the ramp function block.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 764 Ramp acc state BIT 16BIT 0 0 1 ER FVS
This signal indicates whether the acceleration ramp is active.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 766 Ramp dec state BIT 16BIT 0 0 1 ER FVS
This signal indicates whether the deceleration ramp is active.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 934 Ref is 0 BIT 16BIT 0 0 1 ER FVS
This signal is active when the reference is below the limit set in parameter 930 Reference 0 threshold.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 936 Ref is 0 delay BIT 16BIT 0 0 1 ER FVS
This parameter is active when the reference is below the threshold set in parameter 930 Reference 0 threshold. The
signal is enabled after the delay set with parameter 932 Reference delay 0.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 944 Speed is 0 BIT 16BIT 0 0 1 ER FVS
This parameter is active when the speed is below the threshold set in parameter 940 Speed 0 threshold.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 946 Speed is 0 delay BIT 16BIT 0 0 1 ER FVS
This signal is active when the reference is below the threshold set in parameter 940 Speed 0 threshold. The signal is
activated after the delay set in parameter 942 Speed 0 delay.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 1060 Sequencer status UINT16 16BIT 0 0 0 ER FVS

Table of Contents

Other manuals for gefran SIEIDrive ADL300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran SIEIDrive ADL300 and is the answer not in the manual?

gefran SIEIDrive ADL300 Specifications

General IconGeneral
Brandgefran
ModelSIEIDrive ADL300
CategoryInverter
LanguageEnglish

Related product manuals