This signal indicates the state of the “machine states” that controls drive operation.
STS_INIT 0
STS_MAGN 1
STS_STOP 2
STS_START 3
STS_FS_STOP 4
STS_FS_START 5
STS_QSTOP 6
STS_FS_MAGN 7
STS_W_QSTOP 8
STS_READY 9
STS_MAGN_START 10
STS_ALM_DISABLED 11
STS_ALM_END_ACTION 12
STS_ALM_STOP 13
STS_ALM_FSTOP 14
STS_ALM_R_TO_NORMAL 15
STS_READY_START 16
STS_READY_FSTOP 17
STS_ALM_NO_RESTART 18
STS_FS_MAGN_START 19
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 1062 Drive OK BIT 16BIT 0 0 1 ER FVS
This signal is active when the drive is in the “OK” condition and no alarms are present.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 1064 Drive ready BIT 16BIT 0 0 1 ER FVS
This signal is active when the drive reference is in the “Ready” to run condition.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 1110 Digital input E mon BIT 16BIT 0 0 1 ER FVS
These signals represent the state of the corresponding digital input.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 1210 Digital input 1X mon BIT 16BIT 0 0 1 ER FVS
- 1212 Digital input 2X mon BIT 16BIT 0 0 1 ER FVS
- 1214 Digital input 3X mon BIT 16BIT 0 0 1 ER FVS
- 1216 Digital input 4X mon BIT 16BIT 0 0 1 ER FVS
- 1218 Digital input 5X mon BIT 16BIT 0 0 1 ER FVS
- 1220 Digital input 6X mon BIT 16BIT 0 0 1 ER FVS
- 1222 Digital input 7X mon BIT 16BIT 0 0 1 ER FVS
- 1224 Digital input 8X mon BIT 16BIT 0 0 1 ER FVS
- 1226 Digital input 9X mon BIT 16BIT 0 0 1 ER FVS
- 1228 Digital input 10X mon BIT 16BIT 0 0 1 ER FVS
- 1230 Digital input 11X mon BIT 16BIT 0 0 1 ER FVS
- 1232 Digital input 12X mon BIT 16BIT 0 0 1 ER FVS
These signals represent the state of the corresponding digital input on the expansion card.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
- 2388 Torque ref nofilter perc FLOAT 16BIT 0.0 0.0 0.0 ER FVS
The torque control reference current without lter is displayed (in sensorless vector and eld-oriented vector mode).

Table of Contents

Other manuals for gefran SIEIDrive ADL300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran SIEIDrive ADL300 and is the answer not in the manual?

gefran SIEIDrive ADL300 Specifications

General IconGeneral
Brandgefran
ModelSIEIDrive ADL300
CategoryInverter
LanguageEnglish

Related product manuals