24 Filling Hydraulic Systems
Note!
Filling Hydraulic Systems
Hydraulic system for releasing nosepiece, large pressure booster 3-8030
- Unscrew bleeder screw 2-28b at front of riveting gun.
To facilitate bleeding, the riveting gun should be positioned such that the
hose assembly is on an upward incline from the supply unit to the riveting
gun.
- Using an oil can, refill small pressure booster with hydraulic oil via the refill connection until
bubble-free oil flows from the bleeder hole into the oil collection bottle.
- The hydraulic oil in the oil collection bottle can be used for both hydraulic systems.
- Screw bleeder screw back in.
Hydraulic lines and screw connections
Regularly check all lines, hoses and screw connections for leaks and external
signs of damage. Rectify any damage immediately. Oil spraying out can cause in-
juries and fires!
The operating company must ensure that the hose lines are changed at appro-
priate intervals (max. 6 years, including a maximum storage time of 2 years) even
if there are no signs of damage on the hose lines that could impair safety.