9.11 Continuous Test
GAV Settings
9.11 Continuous Test
With the continuous test function, the GAV system can automatically trigger processing cycles
up to a set time or piece number.
During a continuous test it is possible to switch to other menus to observe the statuses, se-
quences, parameters and settings. Parameters and settings can be changed during a continu-
ous test run.
A continuous test can be cancelled at any time with the "ON" or "OFF" button.
Default
Resets all settings to default.
OFF / ON
Switches continuous test off/on.
C
Sets the "piece number" and "time" parameters to 0.
Continuous test
Start delay
Each cycle start is delayed by the set time.
Test without rivets
With the function activated, the vibration feed unit is switched "OFF"
and the "vibration feed unit" fault is suppressed.
Test up to piece num-
ber
The test is stopped on reaching the set value.
Test till time
The test is stopped on reaching the set value.
9
- 50 -
Navigation:
AUTO
►MAN
► Menu
► GAV settings
► Continuous Test
Continuous test menu