GAV Settings
9.1 Vibration Feed Unit
Vibration Feed Unit Settings
(The setting of the proximity switch NS1 is described in Section 9.5 "GAV Settings" - "Separa-
tor".)
Controls the feed rate of the vibration feed unit.
The afterrunning time begins when the proximity switch NS1 on the
separator chute is "ON" (separator chute filled with blind rivets). This
function creates a supply of blind rivets on the separator chute.
The rivet counter is set to the number of blind rivets that are still on the
separator chute after proximity switch NS1 "OFF".
This function prevents the separator from running empty.
Vibration feed unit fault on reaching the set value.
Cannot be set.
Short runtime for normal operation, long runtime when vibration feed
container is empty. This function prevents blind rivets wedging togeth-
er in the event of a backup.
Vibration feed unit fault on reaching the set value.
Resets all settings to default.
Switches the vibration feed unit on or off.
Navigation:
AUTO
►MAN
► Menu
► GAV settings
► Vibration feed unit
Vibration Feed Unit Settings
Menu