11.9.1 Force Calibration
Not in GAV-8000 eco
Process Monitoring
11.9.1 Force Calibration
To perform calibration procedure:
Enter break-off force of calibration mandrels (see calibration mandrel packaging)
Insert calibration mandrel into the spreader nosepiece up to the mandrel head and
connect the spent mandrel container to the spreader nosepiece
Press Cycle button
Repeat steps 2 - 4 up to the specified piece number
Conclude the calibration procedure with End on reaching the specified piece number
Cycle
Executes one processing cycle
Delete
Deletes the data recorded during the last processing cycle
End
Ends the calibration procedure on reaching the specified piece number
11
- 77 -
Navigation:
AUTO
►MAN
► Menu
► Process monitoring
► Cal
► Force
Force calibration menu
1
3
2
4