PROGRAMMING THE DOOR PANEL
131
BUS CODE
CALL CODE
VISIBLE
RESIDENT NAME
BUS CODE
029105
VISIBLE
RESIDENT NAME
BUS CODE
CALL CODE
VISIBLE
RESIDENT NAME
Enables the contact to be made visible in the CONTACTS RESIDENT LIST.
The factory default setting is YES.
To change, press .
CALL CODE
VISIBLE
ACCESS ENABLED?
BUS CODE
Enables ACCESS CONTROL to be activated for the user, with one of the
following options:
(PIN CODE / RFID / RFID & PIN CODE / NO). Factory setting: PIN CODE.
To change, press to select the desired option.
Note: To 'RFID' option, see manual "TCODE/CA NFC NEXA".
VISIBLE
ACCESS ENABLED?
ACCESS CODE
CALL CODE
Enables the code that the user will have to activate(from 0001 to 9999)
ACCESS CONTROL to be dened (see p. 1 ). Using this code, the user25
can activate the relay outputs congured in the ACTIVE OUTPUTS option.
To change, press and the messageACCESS CODE will appear; enter the
access code for the user using the numeric keypad and conrm by
pressing . This must be di ferent for each user.f
Press to restore the previous value.
( ) Bear in mind the number of digits in the configured code (factory setting 4: ,
it will be from 0001 to 9999).
ACCESS CODE
:0000
3 41 2
VISIBLE
ACCESS ENABLED?
ACCESS CODE
CALL CODE
VISIBLE
ACCESS ENABLED?
1234
CALL CODE
Enables the outputs that the user will activate when entering the ACCESS
CODE to be dened. The R1, R2 and P outputs located on the N3301/AL
module, the R3 output corresponds to the output to the CV1 lock release
relay, CV2 of the EL632/EL642 sound module.
To change, press until the required setting is reached.
ACCESS ENABLED?
ACCESS CODE
ACTIVE OUTPUTS
VISIBLE
Enables one of the 8 time slots during which the user will have access using
theACCESS CODE to be dened.
To change the time slots, go to the ACCESS CONTROL option: TIME SLOT
1..8 on p. 1 .29
To change, press until the required setting is reached.
ACCESS CODE
ACTIVE OUTPUTS
TIME FRAME
ACCESS ENABLED?
SETTING RECORDED
Press the button to save the contact if changes have been made, otherwise
the process will be cancelled.
Resident list menu:
Continued from previous page
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANEL WITH DISPLAY
*
*
¿ACCESO ACTIVO?
CÓDIGO ACCESO
ACCESO RFID
VISIBLE
To cards seeNFC ( manual TCODE/CA NFC NEXA).
Continued overleaf