MODULE PROGRAMMING
Factory setting:
- Special codes: Bear in mind the number of digits in the code (see p. 10).
Administrator pin: 271800. 2718 if the number of digits configured = 4.
CP1 button code: 111100. 1111 if the number of digits configured = 4.
CP2 button code: 222200. 2222 if the number of digits configured = 4.
Unlocking code: 333300. 3333 if the number of digits configured = 4.
- Number of digits in user and special codes: Programming field 0 (page 12)
Step 2: 4”– 4 digit code.
- Setting relay 1: Programming field 4 (page 16).
Step 3: 0 Impulse.
Step 4: 03 Activation time (seconds).
- Setting relay 2: Programming field 4 (page 16).
Step 3: 0 Impulse.
Step 4: 03 Activation time (seconds).
- Setting the panic output: Programming field 4 (p. 16).
Step 3: 0 Impulse.
Step 4: 10 Activation time (seconds).
- Setting external push button PL1: Programming field 5 (page 17).
Step 3: 1 Enable/disable the functioning of the push button with button code CP1.
Step 4: 10 Activation time (seconds).
- Setting external push button PL2: Programming field 5 (page 17).
Step 3: 2 Enable/disable the functioning of the push button with button code CP2.
Step 4: 05 Activation time (seconds).
- Setting locking mode: Programming field 6 (page 18).
Step 2: 3 Maximum number of failed attempts to enter user pin.
Step 3: 03 Minimum time between failed attempts (minutes).
Step 4: 03 Duration of locking mode (minutes).
Step 5: 1 The panic output is activated during locking mode.
- Setting identification ID: Programming field 7 (page 19) ( ).Not to be configured
Step 2: 000 Identification ID. Do not modify this field value.
- Setting depth of field: Programming field 8 (page 19) ( ).Not to be configured
Step 2: 3 Depth of field. Do not modify this field value.
Step 3: 0 Direct call disabled. Do not modify this field value.
- Setting the keypad beep: Programming field 9 (see page 20).
Step 2: 1 Beep when keypad buttons pressed (activated).
AUDIO AND VIDEO DOOR ENTRY SYSTEM - ACCESS CONTROL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the golmar NEXA Series and is the answer not in the manual?

golmar NEXA Series Specifications

General IconGeneral
Brandgolmar
ModelNEXA Series
CategoryIntercom System
LanguageEnglish

Related product manuals