21
MODULE PROGRAMMING
Factory setting:
- Special codes: Bear in mind the number of digits in the code (see p. 10).
Administrator pin: 271800. 2718 if the number of digits configured = 4.
CP1 button code: 111100. 1111 if the number of digits configured = 4.
CP2 button code: 222200. 2222 if the number of digits configured = 4.
Unlocking code: 333300. 3333 if the number of digits configured = 4.
- Number of digits in user and special codes: Programming field “0” (page 12)
Step 2: “4”– 4 digit code.
- Setting relay 1: Programming field “4” (page 16).
Step 3: “0” Impulse.
Step 4: “03” Activation time (seconds).
- Setting relay 2: Programming field “4” (page 16).
Step 3: “0” Impulse.
Step 4: “03” Activation time (seconds).
- Setting the panic output: Programming field “4” (p. 16).
Step 3: “0” Impulse.
Step 4: “10” Activation time (seconds).
- Setting external push button PL1: Programming field “5” (page 17).
Step 3: “1” Enable/disable the functioning of the push button with button code CP1.
Step 4: “10” Activation time (seconds).
- Setting external push button PL2: Programming field “5” (page 17).
Step 3: “2” Enable/disable the functioning of the push button with button code CP2.
Step 4: “05” Activation time (seconds).
- Setting locking mode: Programming field “6” (page 18).
Step 2: “3” Maximum number of failed attempts to enter user pin.
Step 3: “03” Minimum time between failed attempts (minutes).
Step 4: “03” Duration of locking mode (minutes).
Step 5: “1” The panic output is activated during locking mode.
- Setting identification ID: Programming field “7” (page 19) ( ).Not to be configured
Step 2: “000” Identification ID. Do not modify this field value.
- Setting depth of field: Programming field “8” (page 19) ( ).Not to be configured
Step 2: “3” Depth of field. Do not modify this field value.
Step 3: “0” Direct call disabled. Do not modify this field value.
- Setting the keypad beep: Programming field “9” (see page 20).
Step 2: “1” Beep when keypad buttons pressed (activated).
AUDIO AND VIDEO DOOR ENTRY SYSTEM - ACCESS CONTROL