Factory setting:
- Special codes: Bear in mind the number of digits in the code (see p. ).73
Administrator pin: 271800. 2718 if the number of digits configured = 4.
CP1 push button code: 111100. 1111 if the number of digits configured = 4.
CP2 push button code: 222200. 2222 if the number of digits configured = 4.
Unlocking code: 333300. 3333 if the number of digits configured = 4.
- Number of digits in user and special codes: Programming field 0 (p. ).75
Step 2: 4”– 4 digit code.
- Setting relay 1: Programming field 4 (p. ).79
Step 3: 0 Impulse.
Step 4: 03 Activation time (seconds).
- Setting relay 2: Programming field 4 (p. ).79
Step 3: 0 Impulse.
Step 4: 03 Activation time (seconds).
- Setting relay 3: Programming field 4 (p. ).79
Step 3: 0 Impulse.
Step 4: 03 Activation time (seconds).
Setting the panic output: Programming field 4 (p. ).79
Step 3: 0 Impulse.
Step 4: 10 Activation time (seconds).
- Setting external push button PL1: Programming field 5 (p. 8 ).0
Step 3: 1 Enable/disable the functioning of the push button with button code CP1.
Step 4: 10 Activation time (seconds).
- Setting external push button PL2: Programming field 5 (p. 8 ).0
Step 3: 2 Enable/disable the functioning of the push button with button code CP2.
Step 4: 05 Activation time (seconds).
- Setting locking mode: Programming field 6 (p. 8 ).1
Step 2: 3 Maximum number of failed attempts to enter user pin.
.
Step 3: 03 Minimum time between failed attempts (minutes).
Step 4: 03 Duration of lock mode (minutes).
Step 5: 1 The panic output is activated during lock mode.
- Setting identification ID: Programming field 7 (p. 8 ).2
Step 2: 000 Identification ID.
- Setting field depth: Programming field 8 (p. 8 ).2
Step 2: 3 field depth.
Step 3: 0 Direct call disabled.
- Setting the keypad beep: Programming field 9 (see p. ).83
Step 2: 1 Beep when keypad buttons pressed (activated).