Programming fields:
Continued from previous page
0 1
0
1
Field “1”: Programming a new activation code (user).
Press 1 to select field 1.
0
1
0 1
Steps: Field + memory position + user pin + outputs + bus code + key button.
2 C
or
(Step 1)
(Step )2
(Step
4)
(Step 7)
Set the memory position number for the location of the new user pin.
Possible memory positions: 001 to 999.
Allows new user pins (from 0000 to 9999) to be created and outputs to be assigned for activation with the created
codes.
Note: Depending on the number of digits configured in field 0 (factory setting = 4).
Number of digits = 4, user pin from 0000 to 9999.
Number of digits = 5, user pin from 00000 to 99999.
Number of digits = 6, user pin from 000000 to 999999.
0 0 0 0 0 0 0 0 0 0 0
0 0
0
(Step 3)
Set the user pin. Possible user pins: 000000 to 999999 with 6 digits. Factory
setting of 4 digits: 0000 to 9999.
(see example of number of digits on page , step 2).75
Duplicate user pins are not allowed.
0
Set the output(s) that the user pin entered in step 3 will activate. Enter one of the following
options or press the key button:
"00" : relay 1 + relay 2 + panic output (terminal P on the terminal block).
"01" : 1.relay
"02" : 2.relay
"03" : relay 1 + relay 2.
"04" : panic output (terminal P on the terminal block).
"05" : relay 1 + panic output (terminal P on the terminal block).
"06" : relay 2 + panic output (terminal P on the terminal block).
"07" : relay 3 (contacts CV1 and CV2 on the sound module).
"08" : relay 3 + relay 1.
"09" : relay 3 + relay 2.
"10" : relay 3 + relay 1 + relay 2.
"11" : relay 3 + panic output (terminal P on the terminal block).
"12" : relay 3 + relay 1 + panic output (terminal P on the terminal block).
"13" : relay 3 + relay 2 + panic output (terminal P on the terminal block).
"14" : relay 3 + relay 1 + relay 2 + panic output (terminal P on the terminal block).
Note: If the key button is pressed, option 1 is set in this value field: relay0 3 + relay 1 +
relay 2, in the value field bus code as 000000 and the programming of the field
finishes. With coded module V03 or later.
0
0 0
0
(Step 5)
0
0 0
Enter the apartment code associated with the user. Possible values are
between 000000 and 255999 or press the key button.
Note: If the key button is pressed, 000000 is set in this value field and
the programming of the field finishes.
*
( )
*
( )
*
( )
(Step 6)
Press the key button to finish programming the field.
Note: It is not necessary to press the key button if it has already been pressed in
step 4 or 5.
Then press the number of the next field to configure or press the C button (cancel) to exit
programming mode.
0
0
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED DOOR PANEL
PROGRAMMING THE DOOR PANEL
*
( )

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the golmar NEXA Series and is the answer not in the manual?

golmar NEXA Series Specifications

General IconGeneral
Brandgolmar
ModelNEXA Series
CategoryIntercom System
LanguageEnglish

Related product manuals