76
Programming fields:
Continued from previous page
0 1
0
1
Field “1”: Programming a new activation code (user).
Press “1” to select field “1”.
0
1
0 1
Steps: Field + memory position + user pin + outputs + bus code + key button.
2 C
or
(Step 1)
(Step )2
(Step
4)
(Step 7)
Set the memory position number for the location of the new user pin.
Possible memory positions: “001” to “999”.
Allows new user pins (from “0000” to “9999”) to be created and outputs to be assigned for activation with the created
codes.
Note: Depending on the number of digits configured in field “0” (factory setting = 4).
Number of digits = 4, user pin from “0000” to “9999”.
Number of digits = 5, user pin from “00000” to “99999”.
Number of digits = 6, user pin from “000000” to “999999”.
0 0 0 0 0 0 0 0 0 0 0
0 0
0
(Step 3)
Set the user pin. Possible user pins: “000000” to “999999” with “6” digits. Factory
setting of “4” digits: “0000” to “9999”.
(see example of number of digits on page , step 2).75
Duplicate user pins are not allowed.
0
Set the output(s) that the user pin entered in step 3 will activate. Enter one of the following
options or press the key button:
"00" : relay 1 + relay 2 + panic output (terminal “P” on the terminal block).
"01" : 1.relay
"02" : 2.relay
"03" : relay 1 + relay 2.
"04" : panic output (terminal “P” on the terminal block).
"05" : relay 1 + panic output (terminal “P” on the terminal block).
"06" : relay 2 + panic output (terminal “P” on the terminal block).
"07" : relay 3 (contacts CV1 and CV2 on the sound module).
"08" : relay 3 + relay 1.
"09" : relay 3 + relay 2.
"10" : relay 3 + relay 1 + relay 2.
"11" : relay 3 + panic output (terminal “P” on the terminal block).
"12" : relay 3 + relay 1 + panic output (terminal “P” on the terminal block).
"13" : relay 3 + relay 2 + panic output (terminal “P” on the terminal block).
"14" : relay 3 + relay 1 + relay 2 + panic output (terminal “P” on the terminal block).
Note: If the key button is pressed, option “1 ” is set in this value field: relay0 3 + relay 1 +
relay 2, in the value field “bus code” as “000000” and the programming of the field
finishes. With coded module V03 or later.
0
0 0
0
(Step 5)
0
0 0
Enter the apartment code associated with the user. Possible values are
between “000000” and “255999” or press the key button.
Note: If the key button is pressed, “000000” is set in this value field and
the programming of the field finishes.
*
( )
*
( )
*
( )
(Step 6)
Press the key button to finish programming the field.
Note: It is not necessary to press the key button if it has already been pressed in
step 4 or 5.
Then press the number of the next field to configure or press the C button (cancel) to exit
programming mode.
0
0
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED DOOR PANEL
PROGRAMMING THE DOOR PANEL
*
( )