CE7000-UM-251-9370 7-65
7 DISASSEMBLY AND REASSEMBLY
Conrming the cables wiring from the Y-motor to the main board
The cables for X and Y motor has same connectors, therefore do not connect those cables incorrectly.
The Y motor has the power cable and the power-relay cable and the encoder cable.
Connect these cables to correct connectors as shown in the picture below.
CE7000-130/130AP/160CE7000-40/60
Main board
Y motor encoder cable
Y motor
Y motor power cable
Y motor power relay cable