EasyManua.ls Logo

GRAPHTEC CE7000-60 - Error Messages in GP-GL Command Mode

GRAPHTEC CE7000-60
278 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CE7000-UM-251-9370 9-16
9 TROUBLESHOOTING
9.6.2 Error Messages in GP-GL Command Mode
Error
code
Error Display Verication item Cause Solution
E02001
Did the plotter write
characters to the
media?
The plotter is
receiving the HP-GL
command.
Set the command
setting to the HP-GL.
PAUSE/MENU -->
Upper position --> 2
COMMAND --> Select
the HP-GL.
Conrm the
command setting
is not set to GP-GL
from AUTO.
The some application
software sets to GP-
GL automatically
even if the command
setting is selecting
the AUTO.
Set the command
setting to the HP-GL.
PAUSE/MENU -->
Upper position --> 2
COMMAND --> Select
the HP-GL.
E02002
Conrm the
application software
is supporting this
plotter.
When wrong
terminator received or
there is no terminator
in the command, this
error is shown.
Set the correct model
name.
Congure your software
application menu to
permit Graphtec plotter
control.
When the USB cable
is using, conrm too
long cable is not
used.
The wrong data is
receiving by noise on
the data cable.
Conrm it is using
good cable.
Use good cable.
When the RS-232C
interface is using,
conrm transport
setting.
The data was missing
while transport via
the interface.
Re-specify the software
application’s interface
conditions.
When the RS-
232C cable is using,
conrm the correct
wiring of cable is
using.
The wrong wiring of
RS-232C cable is
using.
Use the correct wiring of
RS-232C cable.