7 DISASSEMBLY AND REASSEMBLY
7.2.17 Replacing the Y Flexible Cable
How to detach the Y Flexible Cable
(1) Detach the right side cover (Refer to subsection 7.1.1.).
(2) Detach the control panel assembly (Refer to subsection 7.1.3.).
(3) Detach the center cover (Refer to subsection 7.1.4.).
(4) Disconnect the Y exible cable from the main board.
(5) Release the cable ties holding the Y exible cable.
CE7000-130/130AP/60
Main board
Y exible cable
Cable tie
CE7000-40/60
Main board
Y exible cable
Cable tie
(6) Remove the Y exible cable holder on Y slide.
CE7000-130/130AP/60
CE7000-40/60
Y exible cable Y exible cable
Y exible cable holder
Y exible cable holder
(7) Disconnect the Y exible cable from the Y relay board.
CE7000-130/130AP/60CE7000-40/60
Y relay board
Y relay board
Y exible cable
Y exible cable
(8) Peel off the Y exible cable from the Y rail.