9 TROUBLESHOOTING
9.6.3 Error Messages in HP-GL Emulation Mode
If any of the following command errors occur, they are nearly always caused by one of the reasons below:
(1) The software conguration regarding the output device has been changed.
(2) The plotter’s interface conditions have been changed.
When a command error occurs in HP-GL
TM
emulation mode, therefore, rst check the two corresponding
points below:
(1) Congure the software to drive your plotter, and ensure that the software’s interface conditions are
correctly set.
(2) Ensure that the plotter’s interface conditions are set to match those of the software.
Error
code
Error Display Verication item Cause Solution
E03001
Conrm setting on the
application software.
The plotter received
an unrecognizable
command.
The plotter is
receiving the GP-GL
command mostly.
Set the command
setting to the GP-GL.
PAUSE/MENU -->
Upper position --> 2
COMMAND --> Select
the GP-GL.
E03002
Conrm setting on the
application software.
A command was
executed with the
wrong number of
parameters.
Congure your software
application menu to
permit Graphtec plotter
control. Re-specify the
software application’s
interface conditions.
Set the correct model
name if it was incorrect.
E03003
A command
containing an
unusable parameter
was specied.
E03005
An unrecognizable
character set was
specied.
E03006
Coordinates of
command specied
out of cutting area.
E03007
The data being input
exceeds the capacity
of the plotter’s
E03010
Other output
command was
executed while
executing an output
command.