9 TROUBLESHOOTING
Error
code
Error Display Verication item Cause Solution
E03011
Conrm setting on the
application software.
An invalid byte was
received after ESC
code.
Congure your software
application menu to
permit Graphtec plotter
control. Re-specify the
software application’s
interface conditions.
Set the correct model
name if it was incorrect.
E03012
Invalid byte was
received within device
control command.
E03013
A parameter outside
of the permissible
range was specied
in the I/O related
command.
E03014
Too many parameters
in the I/O related
command.
E03015
Framing error, parity
error, or overrun error
has occurred.
Set the RS-232C
transmission condition.
E03016
Interface buffer
memory has
overowed.