CE7000-UM-251-9370 8-4
8 Electrical Adjustment
8.2.3 When the pen block was replaced
When the pen block was exchanged, perform the following adjustments.
Adjust the Registration Mark Sensor Sensitivity (Refer to subsection 8.13.).
Adjust the pen force adjustment values (Refer to subsection 8.11.2.).
Adjust the Offset of Registration Mark Sensor (Refer to subsection 8.14.2.).
Adjust the 2nd Pen Exchange position (Refer to subsection 8.16.2.).
Adjust the Spacing Between Tool 1 and Tool 2 (Refer to subsection 8.17.2.).
End of adjustment
Adjust the X Media Sensor Position (Refer to subsection 8.15.2.).
CE7000-130AP only:
CE7000-40/60/130/160 only:
8.2.4 When the Rear or Front X Media sensor was replaced
When the rear or front X media sensor was exchanged, perform the following adjustment.
Adjust the X Media Sensor Position (Refer to subsection 8.15.2.).
End of adjustment
8.2.5 When the registration mark sensor was replaced
When the registration mark sensor was exchanged, perform the following adjustments.
Adjust the Registration Mark Sensor Sensitivity (Refer to subsection 8.13.).
Adjust the Offset of Registration Mark Sensor (Refer to subsection 8.14.2.).
End of adjustment