CE7000-UM-251-9370 8-8
8 Electrical Adjustment
8.4 Explanation of the Values of the Main Board Settings
The default factory adjustment values are recorded on label in the location shown below.
When the SUB-NVRAM of adjustment values are not able to copy to the main board, use this values.
If you have changed any values by making adjustments, record those values for the next maintenance check.
CE7000-130/130AP/160
CE7000-40/60
20 40 60 150 240 0.2 202.10 351.78 -0.2 0.2 0.7 1.1
Explanation of the values
PEN ADJ Pen force adjustment values for each target force.
DISTANCE X and Y for the distance adjustment value, Z for the diagonal distance value
used to the right angle adjustment.
REM SENS X and Y for the offset adjustment value of the registration mark sensor
position.
(This is not recorded for CE7000-120AP.)
MEDIA SENS Front and rear media sensor position adjustment values.
1-2TOOL 1 - 2 Tool spacing adjustment value.
(This is recorded for CE7000-120AP.)
PENSEL Pen exchange position adjustment value.
(This is recorded for CE7000-120AP.)