EasyManua.ls Logo

GRAPHTEC CE7000-60 - Page 150

GRAPHTEC CE7000-60
278 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CE7000-UM-251-9370 8-7
8 Electrical Adjustment
Factory presets (Normal Mode)
This setting depends on the model.
Dip Switch (SW1) 1 2 3 4 5 6 7 8 Model
12345678
ON
OFF
OFF OFF OFF OFF OFF OFF OFF OFF CE7000-40
12345678
ON
OFF
ON OFF OFF OFF OFF OFF OFF OFF CE7000-60
12345678
ON
OFF
OFF ON OFF OFF OFF OFF OFF OFF CE7000-130
12345678
ON
OFF
ON ON OFF OFF OFF OFF OFF OFF CE7000-160
12345678
ON
OFF
OFF ON ON OFF OFF OFF OFF OFF CE7000-130AP
Note:
The NOV-RAM CLEAR must perform when the dip switch setting was changed from previous model setting.
NOV-RAM Clear
All adjustment values are cleared to the default value of each model when the NV-RAM CLEAR was
performed.
Dip Switch (SW1) 1 2 3 4 5 6 7 8 Model
12345678
ON
OFF
OFF OFF OFF ON OFF OFF OFF OFF CE7000-40
12345678
ON
OFF
ON OFF OFF ON OFF OFF OFF OFF CE7000-60
12345678
ON
OFF
OFF ON OFF ON OFF OFF OFF OFF CE7000-130
12345678
ON
OFF
ON ON OFF ON OFF OFF OFF OFF CE7000-160
12345678
ON
OFF
OFF ON ON ON OFF OFF OFF OFF CE7000-130AP

Table of Contents

Other manuals for GRAPHTEC CE7000-60

Related product manuals