CE7000-UM-251-9370 35
9 TROUBLESHOOTING
9.7.4 Conrm the Cutting Data
Output of the dump list of the cutting data received by the plotter is possible. It is used to check if the
transmission of cutting data is performed correctly.
Operation
(1) Set a media larger than A4 size.
(2) Set the pen tool to the tool carriage and select the condition where the pen tool is set.
(3) Press the PAUSE/MENU key to display the menu below.
(4) Press the Left position (
t
) key (TEST) to display the menu below.
(5) Press the F3 key (DATA DUMP) to display the menu below.
(6) Conrm that the pen tool is set.
(7) Conrm that operation area of tool and media is safe.
(8) Press the F1 key (DONE).
(9) Output the data to plotter from the PC. The dump list starts when the plotter received the data.
To stop the dump list
(1) Quit outputting at the PC, and then turn off the power for the plotter.