CE7000-UM-251-9370 8-33
8 Electrical Adjustment
(4) Press the Right position key to display the adjustment menu shown below.
(5) Press the Up position key to display the following menu.
(6) Press the F2 key to display the following menu.
(7) Press the F2 key to display the following menu.
UP and down allow keys changes value
(8) Input the X-offset adjustment value from the recorded value of registration mark of X offset.
(9) Press the ENTER key to set the X offset, the following menu is displayed.
(10) Press the F3 key to display the following menu.
UP and down allow keys changes value
(11) Input the Y-offset adjustment value from the recorded value of registration mark of Y offset.