FCX4000-UM-251-9370 7-28
7 DISASSEMBLY AND ASSEMBLY
(7) Disconnect the X Flexible cable from the main board and release the X exible cable from the cable tie.
X Flexible cable
Cable tie
(8) Disconnect the X Flexible Cable from the Y relay board.
X exible cable
Y relay board
(9) Detach the X Flexible Cable from the rear bottom cover.
How to reinstall the X Flexible Cable
(1) Prepare the following size of double-sided tapes when the X Flexible cable is going to replace.
Three 10 x 30 mm double-sided tape
(2) Fold the new X Flexible cable as shown in the picture below.
45 degree
45 degree 45 degree
160 mm
254mm
110 mm
295mm
320 mm
This side has
contact terminal.
Reinforcement plate
This side has contact terminal.
Mountain fold with right angle
Mountain fold with right angle
Valley fold
Valley fold
Valley fold
Valley fold with right angle
Valley fold
Valley fold