MOTOR AND DRIVING SYSTEM CU800 Service Manual
97
Battery voltage (5100,1) is greater than rated maximum
voltage for controller for longer than 1s.
Capacitor voltage (5100,3) is greater than rated
maximum voltage for controller for longer than 1s.
Motor in low voltage cutback
Motor control (DC link) has entered low voltage cutback
region.
Motor in high voltage cutback
Motor control (DC link) has entered high voltage cutback
region.
The voltage applied to the KL15/30 is below the
controller rated minimum
Low heatsink temperature (5100,4) has reduced power
to motor
High heatsink temperature (5100,4) has reduced power
to motor
High measured (4600,3) or estimated (4602,8) motor
temperature has reduced power to motor
Low Measured temperature has reached -30deg
Controller is in pre-operational state
Controller has not received all configured RPDOs at
power up
One or more configured RPDOs not received with 3s at
start up or 500ms during normal operation.
Encoder Alignment Warning
Encoder is not aligned properly.
SinCos Encoder Min Max Values are heading towards a
voltage rail or converging together.
A Error ride through event has been encountered, but
operation is allowed to continue although the system
may be derated
The open loop VF induction motor software has detected
a pulled-out condition, it will automatically attempt to
restart.
Stator resistance thermal compensation has failed due to
the estimated value being too different from the
configured value
Encoder PLL Deactivated
Warning
Encoder PLL has turned off due to poor tracking
Vehicle is operating in reduced power mode as some
CAN messages are not being received (Renault only)
Scheduler stack overflow
warning
This warning is set if any task has between 10% and
20% of its stack free.
Internal supply out of range
warning
An internal logic supply rail has gone out of range
CAN open anon EMCY level 1
EMCY message received from non-Sevcon node and
anonymous EMCY level (2830,0) is set to 1.
Vehicle service next due time (2850,5) has expired. If
supported Service drivability profile (2925) will activate.
Valid direction selected with operator not seated or
operator is not seated for a user configurable time in
drive.
Both the forward and reverse switches have been active
simultaneously for greater than 200ms.