Contents
Preparing for installation ················································································ 1
Safety recommendations ··································································································································· 3
Examining the installation site ···························································································································· 3
Temperature/humidity ································································································································ 3
Cleanliness ················································································································································· 3
EMI ····························································································································································· 4
Laser safety ················································································································································ 4
Installation tools ················································································································································· 5
Installing the switch ························································································ 6
Installing the switch in a 19-inch rack················································································································· 6
Mounting brackets ······································································································································ 6
Attaching the mounting brackets to the switch ··························································································· 8
Rack-mounting the switch ························································································································ 10
Mounting the switch on a workbench ··············································································································· 11
Mounting the switch on a wall ·························································································································· 12
Grounding the switch ······································································································································· 13
Grounding the switch with a grounding strip ···························································································· 14
Grounding the switch with a grounding conductor buried in the earth ground ········································· 15
Installing and removing power modules ··········································································································· 15
Installing a power module ························································································································ 16
Removing a power module ······················································································································ 17
Connecting the power cord ······························································································································ 17
Connecting the AC power cord for the fixed AC power module (method 1) ············································ 18
Connecting the AC power cord for the fixed AC power module (method 2) ············································ 19
Connecting the DC power cord for the fixed DC power module (method 1) ············································ 20
Connecting the DC power cord for the fixed DC power module (method 2) ············································ 21
Connecting the power cord for a PSR75-12A/PSR150-A1 power module ·············································· 22
Connecting the power cord for a PSR150-D1 power module ·································································· 23
Verifying the installation ··································································································································· 24
Accessing the switch for the first time ·························································· 25
Setting up the configuration environment ········································································································ 25
Connecting the serial console cable ················································································································ 26
Connecting the micro USB console cable ········································································································ 27
Setting terminal parameters ····························································································································· 29
Powering on the switch ···································································································································· 29
Setting up an IRF fabric ··············································································· 30
IRF fabric setup flowchart ································································································································ 30
Planning IRF fabric setup ································································································································· 31
Planning IRF fabric size and the installation site ······················································································ 31
Identifying the master switch and planning IRF member IDs ··································································· 31
Planning IRF topology and connections··································································································· 31
Identifying IRF physical ports on the member switches ··········································································· 32
Planning the cabling scheme ··················································································································· 34
Configuring basic IRF settings ························································································································· 35
Connecting the IRF physical ports ··················································································································· 35
Verifying the IRF fabric setup ··························································································································· 36
Maintenance and troubleshooting ································································ 37
Fixed power module failure ······························································································································ 37
Symptom ·················································································································································· 37
Solution ···················································································································································· 37
Removable power module failure ···················································································································· 38
Symptom ·················································································································································· 38
Solution ···················································································································································· 38

Table of Contents

Other manuals for H3C S5130S-EI series

Questions and Answers:

H3C S5130S-EI series Specifications

General IconGeneral
SeriesS5130S-EI
CategorySwitch
MAC Address Table Size16K
VLAN4K VLANs
ManagementWeb, CLI, SNMP
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Operating Humidity5% to 95% (non-condensing)
Ports10/100/1000BASE-T ports
Layer SupportLayer 3
StackingSupported
Power SupplyAC/DC
PoESupported on some models
Dimensions (W x D x H)440 x 43.6 mm

Summary

Preparing for Installation

Safety Recommendations

General safety guidelines for switch installation, including handling, environment, and power.

Installing the Switch

Installing the Switch in a 19-inch Rack

Guidance on mounting the switch into a standard 19-inch rack.

Rack-mounting the Switch

Steps for securing the switch chassis into a rack using mounting brackets.

Grounding the Switch

Crucial steps for connecting the switch grounding cable for safety.

Installing and Removing Power Modules

Procedures for installing and removing switch power modules.

Connecting the Power Cord

General guidelines and table for connecting power cords to various switch models.

Verifying the Installation

Checks to ensure proper installation, connectivity, and power.

Accessing the Switch for the First Time

Setting up the Configuration Environment

Configuring the terminal environment for switch access.

Setting Terminal Parameters

Required terminal emulator settings for console access.

Powering on the Switch

Steps and prerequisites for powering on the switch.

Setting up an IRF Fabric

Maintenance and Troubleshooting

Fixed Power Module Failure

Diagnosing and resolving fixed power module issues using LEDs.

Removable Power Module Failure

Troubleshooting steps for removable power module failures.