27
5. Set the control action to take when monitored traffic exceeds the upper threshold.
storm-constrain control { block | shutdown }
By default, storm control is disabled.
6. Enable the Ethernet interface to output log messages when it detects storm control threshold
events.
storm-constrain enable log
By default, the Ethernet interface outputs log messages when monitored traffic exceeds the
upper threshold or drops below the lower threshold from a value above the upper threshold.
7. Enable the Ethernet interface to send storm control threshold event traps.
storm-constrain enable trap
By default, the Ethernet interface sends traps when monitored traffic exceeds the upper
threshold or drops below the lower threshold from the upper threshold from a value above the
upper threshold.
Changing a Layer 2 Ethernet interface to an FC interface
About changing a Layer 2 Ethernet interface to an FC interface
This feature allows you to change a Layer 2 Ethernet interface to an FC interface. Support for this
feature depends on the Layer 2 Ethernet interface type and device model.
Restrictions and guidelines
After you configure this feature on a Layer 2 Ethernet interface, the system deletes the interface,
creates the FC interface, and enters FC interface view. This feature does not modify the interface
number.
Procedure
1. Enter system view.
system-view
2. Enter Layer 2 Ethernet interface view.
interface interface-type interface-number
3. Change the Layer 2 Ethernet interface to an FC interface.
port-type fc
By default, the interface operates as a Layer 2 Ethernet interface.
4. (Optional.) Change the FC interface back to a Layer 2 Ethernet interface.
port-type ethernet
By default, the interface operates as a Layer 2 Ethernet interface.
Enabling bridging on an Ethernet interface
About enabling bridging on an Ethernet interface
By default, the device drops packets whose outgoing interface and incoming interface are the same.
To enable the device to forward such packets rather than drop them, enable the bridging feature in
Ethernet interface view.
Restrictions and guidelines
Ethernet service instance configuration and bridging are mutually exclusive on an interface.
Procedure
1. Enter system view.

Table of Contents

Other manuals for H3C S6850 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C S6850 Series and is the answer not in the manual?

H3C S6850 Series Specifications

General IconGeneral
BrandH3C
ModelS6850 Series
CategorySwitch
LanguageEnglish

Related product manuals