Measurement procedure
MP85A A0293_06_E00_03 HBM: public 83
Internal memory
(RAM):
Current
parameter set/
measurement program
Internal flash
(EEPROM):
31 parameter sets
+ factory settings
MMC/SD card:
1000 parameter sets
Fig. 8.17 Measurement program processing
In addition, e.g. for data backup, you can transfer parameter sets to the MMC/
PC card of the MP85A process controller or connected computer. You require
the PME Assistant or INDUSTRYmonitor software for transfer to a PC.
Tip
The optional memory card (MMC/SD card) can store another 1000 parameter
sets in binary data format, in addition to the 31 parameter sets in XML data
format. The method of functioning and processing speed are identical for both
file types.
Processing the system parameters
The system parameters include the basic settings, interface settings, passcode
and settings for data backup and MP85A process controller statistics. You can
find a complete list of all system parameters in the MP85A interface descrip
tion.